DC-DC Converters - Standard Series

Convert 20-50 VDC to 12 or 24 VDC negative ground output for powering communication/navigation
equipment, on negative ground systems. Ideal for powering voice and data transceivers in mobile applications.
• Excellent Regulation: Output voltage maintained within 1% under all line and load
conditions within rating (except 3 amp models).
• Heat generated by semi-conductors is extracted and dissipated by large heat sink fins
that maximize air contact for cool operation and long life of components.
• Polyurethane conformal coating on PC boards and corrosion-resistant anodized aluminum
case with heavy duty shock mounts assure survival in hostile environments.
• Numerous converter and load protection circuits: Current limiting*; automatic thermal
shutdown; short circuit proof*; reverse polarity and over voltage protection*.
* Except 3 Amp. Model.
|
Model |
Input voltage |
Output voltage |
Output Amps |
Case Size |
Weight |
||
|
Intermittent |
Continuous |
(Lbs) |
(Kg.) |
||||
|
Standard Series |
|||||||
|
32-12-3 |
20-40† |
13.6 |
3 |
2 |
C-1 |
2 |
.9 |
|
32-24-3 |
32-40† |
24.5 |
3 |
2 |
C-1 |
2 |
.9 |
|
32-12-6 |
20-50 |
13.6 |
6 |
6 |
C-10 |
2.5 |
.9 |
|
32-24-6 |
32-50 |
24.5 |
6 |
6 |
C-10 |
2.5 |
.9 |
|
32-12-10 |
20-50 |
13.6 |
10 |
10 |
C-2 |
4 |
1.8 |
|
32-24-10 |
32-50 |
24.5 |
10 |
10 |
C-2 |
4 |
1.8 |
|
32-12-15 |
20-50 |
13.6 |
15 |
15 |
C-2 |
5 |
2.3 |
|
32-24-15 |
32-50 |
24.5 |
15 |
15 |
C-2 |
5 |
2.3 |
|
32-12-25 |
20-50 |
13.6 |
25 |
20 |
C-3 |
7.5 |
3.4 |
|
32-24-25 |
32-50 |
24.5 |
25 |
20 |
C-3 |
7.5 |
3.4 |
|
32-12-35 |
20-50 |
13.6 |
35 |
30 |
C-4 |
12 |
5.5 |
|
32-24-35 |
32-50 |
24.5 |
35 |
30 |
C-4 |
12 |
5.5 |
|
32-12-50 |
20-50 |
13.6 |
50 |
40 |
C-5 |
16 |
7.3 |
|
32-24-50 |
32-50 |
24.5 |
50 |
40 |
C-5 |
16 |
7.3 |
Performance Specifications Standard & Isolated Series
Output: 13.6 VDC (internally adjustable 12.6-14.5) or 24.5 VDC (or specify)
Ripple: 150 mV P-P maximum
Regulation: 1% Line/Load (32-12-3/32-24-3)
Duty Cycle Ratings*
Intermittent - 20 minutes max on time, 20% duty. Current limit set at approx. 105% of intermittent rating
Continuous - 24 hours, 100% duty
Idle Current: Less than 100 mA (including power “ON” light )
Operating Temp: 0-50° C, Derate Linearly From 100% @ 40° C To 50% @ 50° C Thermal shutdown @ 70° C Case Temperature
Switching Frequency: 40 Khz*
Efficiency: 85% - Typical.†
Isolation:
Output/Chassis; Input/chassis: 250 VDC
Certification: Carries the CE mark
*except 32-12-3 Linear, Non-Switching
†except 32-12-3 50% @ 24 VDC Input
|
Case |
inches |
Centimeters |
||||
|
H |
W |
D |
H |
W |
D |
|
| C-1 | 2.7 | 4.5 | 6.0 | 6.9 | 11.4 | 15.2 |
| C-2 | 4.5 | 5.9 | 11.0 | 11.4 | 15.0 | 27.9 |
| C-3 | 6.0 | 4.7 | 14.0 | 15.2 | 11.9 | 35.6 |
| C-4 | 6.0 | 4.7 | 16.0 | 15.2 | 11.9 | 40.6 |
| C-5 | 6.2 | 6.8 | 18.1 | 15.7 | 17.3 | 46.0 |
| C-10 | 2.8 | 4.2 | 10.4 | 7.1 | 10.7 | 26.4 |
Isolated and ISP Series Converters Available – contact factory
Features: reverse polarity protection; input fuse; output fuse; current limiting, short circuit proof out; automatic resetting thermal shutdown; input transient protection*; high/low input voltage shutdown; polyurethane conformal coating on PC board; Power “ON” light; On/off switch; *ISP Series only
Options
• Operation as battery charger or parallel redundant operation* derate to continuous duty rating (contact factory)
• Extreme vibration mounting kit. (See below)
* Except Model: 32-12-3.
|
|
|
|
Extreme vibration mounting kit The Extreme Vibration Mounting Kit is available to protect NEWMAR power converters from the extreme stresses of shock and vibration when mounted on highvibration vehicles. The kit (pictured here) replaces the standard vibration kit provided with the unit and fits into the unit's mounting flange to act as a "super shock absorber" for electronics in high-vibe applications. It is available to fit all NEWMAR units from 2 to 70 lbs. Specify KITL for units which weigh 215 lbs. and KitH for units which weigh 16-70 lbs. |
![]() |
|
|
|