Download PDF Data Sheet

Phase Three “Smart” battery charging technology provides significant benefits over traditional float chargers whose output voltage droops under heavy loads, and fails to attain absorption voltage levels recommended by battery manufacturers as part of a proper charge cycle. Theses issues are particular significant in Emergency Vehicle applications where rapid recharge is required while powering DC loads, and reliable service life of a battery is critical. Smart Chargers interact with batteries and deliver a three stage charge process which provides for fastest recovery and ideal battery condition, maximizing performance and life.

Adaptability to different battery types and charge conditions is another important feature. A selector switch adjusts output voltage to adapt for proper charging of gel-cell, lead acid and AGM battery types. An optional temperature compensation sensor adjusts output for ideal voltage based on changes in ambient temperatures. This improves performance and extends battery life.

Features
• “Smart” circuitry provides three stage charging—bulk, absorption, float
• Gel-Cell/Flooded Lead-acid/AGM battery type switch selects optimum
charge/float voltages
• Multiple isolated outputs - charge independent battery banks*
• Optional sensor adjusts output voltage based on battery temperature*
• Current limiting - charges dead batteries without overload
• Use as a power supply; can power Radios/MDT’s without a battery in line
• Built to last—rugged stainless steel case with circuitry hardened for hostile environments

*Except PT-7

12 Volt
24 Volt
PT-7
PT-24-8
PT-14
PT-24-13
PT-25
PT-24-20
PT-40
PT-24-40
PT-70A
PT-24-45F
PT-24-60F
PT-24-95F
Detailed specifications below.

Specifications
12 Volt Models
PT-7
PT-14
PT-25
PT-40
PT-70A
Input VAC
(50-60 Hz.)
88-132 or
176-264
85-264
90-132 or
180-264
85-135 or
170-270
90-264
Input Amps @ Full Load
@ 115 VAC
2
2.8
6.5
8.5
12
@ 230 VAC
1
1.4
4
4.3
6
P.F. Rating
>.65
.98@115V
.95@230V
.7
.7
.95@230V
.98@115V
Max Output Amps
@ 115 VAC Input
7
14
25
40
64
@ 230 VAC Input
7
14
25
40
70
Output Banks
2
3
3
3
3
Battery Capacity
Amp-Hours
14-70
28-140
50-250
80-400
140-700
Operating Temp.
Rating Ref.
T-2
T-2
T-7
T-1
T-2
Weight; Lbs./Kg.
3.2/1.5
8/4
8.2/4
12/6
15.2/7
Case Size Ref.
A-1
A-2
A-2
A-3
A-5
Optional Temp
Sensor Model
N/A
TCS-12/24
TCS-12/24
TCS-12/24
TCS-12/24

24 Volt Models
PT-24-8
PT-24-13
PT-24-20
PT-24-40
PT-24-45F
PT-24-60F
PT-24-95F
Input VAC
(50-60 Hz.)
85-264
90-132 or
180-264
85-135 or
170-270
90-264
207-253
207-253
207-253
Input Amps @ Full Load
@ 115 VAC
2.8
6.5
8.5
12
N/A
NA
N/A
@ 230 VAC
1.4
4
4.3
6
8
13
17
P.F. Rating
.95@230V
.98@115V
.7
.7
.95@230V
.98@115V
.7
.7
.7
Max Output Amps
@ 115 VAC Input
8
13
20
37
N/A
NA
N/A
@ 230 VAC Input
8
13
20
40
45
60
95
Output Banks
3
3
3
3
3
3
3
Battery Capacity
Amp-Hours
16-80
26-130
40-200
80-400
90-450
150-600
180-950
Operating Temp.
Rating Ref.
T-2
T-2
T-1
T-2
T-3
T-3
T-3
Weight; Lbs./Kg.
8/4
8.2/4
12/6
15.2/7
12.2/6
34.0/15
34.0/15
Case Size Ref.
A-2
A-2
A-3
A-5
A-4
A-7
A-6
Optional Temp
Sensor Model
TCS-12/24
TCS-12/24
TCS-12/24
TCS-12/24
TP
TP
TP

Case Size
Ref
Inches
Centimeters
H
W
D
H
W
D
A-1
10.5
5.0
2.8
26.7
12.7
7.1
A-2
12.5
7.7
4.3
31.8
19.6
10.9
A-3
14.1
9.5
4.0
35.8
24.1
10.2
A-4
15.5
9.7
5.0
39.4
24.6
12.7
A-5
16.7
9.8
6.7
42.4
24.9
17.0
A-6
19.5
12.2
8.2
49.5
40.0
20.8

Temperature Rating References
T-1
-25˚C to +60˚C; Derate linearly from 100% @ 50˚C to 75% @ 60˚C
T-2
-10˚C to +60˚C; Derate linearly from 100% @ 50˚C to 80% @ 60˚C
T-3
-20˚C to +50˚C; Derate linearly from 100% @ 45˚C to 70% @ 60˚C

Nominal Output Voltages at Gel/Flooded Switch Settings
(Without Temperature Compensation option installed or at 22.2˚C (72˚F) with Temperature Compensation option installed.)
 
12 Volt Models
24 Volt Models
32 Volt Model
Setting
Charge @
50 % load
Float @
.5 amp load
Charge @
50 % load
Float
@ .5 amp load
Charge @
50 % load
Float @
.5 amp load
Gel-Cell
14.0 VDC
13.6 VDC
28.0 VDC
27.2 VDC
37.3 VDC
36.2 VDC
Flooded/AGM
14.2 VDC
13.4 VDC
28.4 VDC
26.8 VDC
37.8 VDC
35.7 VDC

Power Returned to Battery by 14 Amp 3-Step Charger vs 15 Amp Float Charger
Conditions: 200 AH Battery, 75% Charged, 4 Amp Constant Load



The graph depicts the incremental power returned to batteries using a three step process which controls voltage depending on battery and load conditions, in comparison to float type chargers that regulates to a single end of charge voltage set point.

Temperature Compensation:
- 5 mV per cell per ˚C. Sensor supplied with 25' cable and plug-in connector

Protection (all models):
Input/Output Fuses, Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield

Remote Panel, Model RP:
LED's indicate charger output stage. Button allows manual reinitialization of three stage charge cycle. Supplied with 25' cable and plug-in connector. Panel dimensions: 3" H x 4.75" W

Optional Accessories
Battery Preserver
Battery Preserver
Click Here
Temperature
Compensation Sensor

Model: TCS-12/24 shown - see above for applicable sensor depending on charger model.
Kwik-Eject™
Click Here
Battery Monitor,
Click Here